Accident: Auster 5 Series J1, EI-AUM, Seven Parks Farm Co. Dublin, 21 March 2010: Report No 2010-017

October 19, 2010

SYNOPSIS

On landing, the aircraft veered to the right, ground-looped and impacted a boundary fence.

Accident: Avid Mk IV Speedwing, G-BTMS, 5 nm southwest of Tuskar, 11 August 2009: Report No 2010-016

October 13, 2010


SYNOPSIS


The aircraft departed Haverfordwest Airport in Wales at 16.00 hrs en-route to Taghmon in Co. Wexford.  After approximately 55 minutes flying time the engine stopped without warning.  The Pilot immediately selected the other fuel tank and attempted to re-start the engine.  With the aircraft descending through 900 ft the restart attempt was abandoned and a successful ditching was carried out.  The Pilot was not injured.  The Investigation found that the engine stopped probably due to fuel starvation relating to a fuel-vapour related problem.


Serious Incident: Cessna 180K, N71763, Private Airfield Co. Meath, 9 August 2009: Report No 2010-015

September 21, 2010


SYNOPSIS

The aircraft was on approach to a private airfield in Co. Meath when it struck cables.  The aircraft climbed away and landed safely at another airfield.  The aircraft suffered minor damage and there were no injuries.


Accident: Cessna 206G Stationair, EI-HOG, Clonbullogue Airfield Co. Offaly, 15 March 2009: Report No. 2010-014

September 14, 2010

SYNOPSIS

The aircraft, which had recently commenced operation with the parachute club, suffered a temporary partial power loss at 9,000 ft as it climbed to drop its parachutists.  On the Pilot"s command, the parachutists exited the aircraft.  The engine recovered but subsequently stopped during the final approach.  This resulted in the aircraft landing short of the runway in a ploughed field and inverting.  The Pilot was taken to hospital but was later discharged.

The Investigation found that the engine stopped due to fuel exhaustion, which was caused by an inappropriate method of monitoring the fuel consumption and fuel quantity on board the aircraft.  A contributory factor was lack of operational experience with a new aircraft type. 

Two Safety Recommendations are issued; one to the Operator regarding its fuel management system and one to the Federal Aviation Administration (FAA) regarding fuel settling post refuelling.

 

Accident: Pipistrel Taurus 503, EI-ECS, Birr Airfield Co. Offaly, Ireland, 6 December 2008: Report No 2010-013

September 2, 2010


SYNOPSIS

The new motor glider took off from Birr Airfield (EIBR) on a check flight prior to issuance of a Permit to Fly.  There were two persons on board, the Check Pilot and the Owner. During the climb the engine suddenly stopped and subsequent attempts to restart it failed.  An attempt was made to return to the airfield but the aircraft became low on approach.  In attempting a forced landing into a field short of EIBR the aircraft struck the topmost branches of a tree and descended into a garden.  Neither occupant was injured other than minor cuts.  The Pilot candidly stated that he had misjudged the approach back to the airfield, having been distracted by the engine stoppage and the attempts to restart it. The Emergency Services attended and were warned by the crew that an unmarked ballistic parachute, an explosive rocket device, was installed on the aircraft.

Four Safety Recommendation are issued as a result of this Investigation: Three Safety Recommendation are issued; to the Irish Aviation Authority (IAA), to the European Aviation Safety Agency (EASA) and to the State of Slovenia requiring that warning placards are placed on the outside of an aircraft, when such an aircraft is equipped with a ballistic parachute system.  A fourth Safety Recommendation is issued to Pipistrel concerning the provision of information in the Flight Manual regarding the possibility of sudden engine stoppage.


Serious Incident: Gulfstream IV SP, VT-MST, near Killarney Co. Kerry, Ireland, on 13 July 2009: Report 2010-012

August 30, 2010

SYNOPSIS

The aircraft departed from Runway (RWY) 08 at Kerry Airport (EIKY) on a flight to Luton, England (EGGW).  Shortly after take-off, the left hand windshield fractured and the crew requested a return to EIKY.  Kerry Tower cleared the aircraft to return using a procedure to establish on the Instrument Landing System (ILS) approach for RWY 26.  The aircraft initiated the procedure but then commenced a descent, in cloud, on a track approximately parallel to the ILS but 6 nautical miles (nm) south of it.  A radar controller in Shannon, who had been monitoring but not controlling the flight, intervened by phone with Kerry Tower and directed that Kerry Tower should instruct the aircraft to climb immediately. 

Contemporaneously, the aircraft’s Enhanced Ground Proximity Warning System (EGPWS) alerted the crew.  The aircraft reached a lowest height above the ground of 702 ft before commencing a climb.  Kerry Tower handed it over to a radar controller at Shannon for guidance onto the ILS but the aircraft encountered further navigational difficulties before landing.  On subsequent technical inspection, it was also found that the No. 1 engine had sustained serious foreign object damage and that an engine change was required.

Incident: Powered para-glider, Salterstown Co. Louth, 26 July 2009: Report No 2010-011

August 19, 2010



Synopsis

After a flight of one hour, the Pilot decided to practise a forced landing exercise. He overshot the landing point and struck power lines near the field boundary. The para-glider suffered minor damage but there was a loss of power to a significant number of electricity users as a result of the incident.



Accident: Eiriavion PIK-20D (Glider), G-EDMV, near Durrow, Co. Laois, 15 July 2009

August 13, 2010


SYNOPSIS


The glider was carrying out a closed-circuit cross-country flight from Birr Airfield, Co. Offaly (EIBR). Due to deterioration in the weather conditions, the Pilot decided to make an unscheduled out-landing in a field near Durrow, Co. Laois. The glider landed on a down-slope, and the Pilot ground looped to the right to avoid impacting the field boundary fence and hedge. The fuselage sustained significant damage during the ground loop manoeuvre.

 

Accident: Schweizer Model 269C-1, EI-CZL, Near Kilshanchoe, Co. Kildare, 1 Apr 2009: Report No 2010-009

August 5, 2010

SYNOPSIS

The helicopter departed Weston Airport (EIWT) at 16.02 hrs on a training flight with an Instructor and Student on board.  The Instructor stated to Dublin Air Traffic Control (ATC) that his intention was to operate south of Enfield between 1,000 and 2,000 ft.  The last communication with Dublin ATC was at 16.12 hrs as the helicopter transited into Class G airspace[1] outside the Dublin Control Zone (CTR).  Following this exchange, no further communication was made.  During a probable low-level transition after a practice autorotation (Section 1.18.1 Autorotation), the helicopter impacted disused electrical power lines at Kilshanchoe, Co. Kildare. An alert was raised following enquires made by family members the following morning.  The wreckage of the helicopter was located the following morning by an Irish Coast Guard helicopter.  The accident was not survivable and both occupants were fatally injured.  There was no fire.

[1] Class G airspace:All uncontrolled airspace within the Shannon FIR except for those areas designated as Class A and Class C.

 

 

Serious Incident: Airbus A319-132, D-AGWK, 27 May 2008, Report No. 2010-008

July 15, 2010

_x000D_

_x000D_

_x000D_

_x000D_

_x000D_

SYNOPSIS _x000D_

The aircraft had departed Dublin and was climbing towards cruising altitude when the Purser reported to the Captain that another Cabin Crew Member (CCM) appeared unwell and that passengers appeared to have fallen asleep quickly after take-off. Following a discussion the flight crew went on oxygen, declared an emergency and returned to Dublin where the aircraft landed without further incident. No defect was subsequently found on the aircraft. The report of the Investigation makes three safety recommendations.

_x000D_

_x000D_

_x000D_